[4] CHECK POINT OF EVERY 100 HOURS

Changing Engine Oil
1. See page G-6.
Cleaning Air Cleaner Element
1. Remove the element (1).
2. Clean the element :
• When dry dust adheres to the element, blow compressed air from
the inside turning the element. Pressure of compressed air must
be under 205 kPa (2.1 kgf/cm
• When carbon or oil adheres to the element, soak the element in
detergent for 15 minutes then wash it several times in water,
rinse with clean water and dry it naturally. After element is fully
dried, inspect inside of the element with a light and check if it is
damaged or not.
(Referring to the instructions on the label
attached to the case.)
3. Replace the air cleaner element (1) :
Once a yearly or after every six times of cleaning, whichever
comes first.
NOTE
• Check to see if the evacuator valve (3) is blocked with dust.
IMPORTANT
• The air cleaner uses a dry element, never apply oil.
• Do not run the engine with filter element removed.
• Be sure to refit the dust cup with the arrow ↑ (on the rear)
upright. If the dust cup is improperly fitted, dust passes by
the baffle and directly adheres to the element.
Evacuator Valves (3)
Open the evacuator valve once a week under ordinary conditions
or daily when used in a dusty place to get rid of large particles of dust
and dirt.
(1) Air Cleaner Element
(2) Cover
G-18
G GENERAL
2
, 30 psi)
(3) Evacuator Valve
W1033621
W1033675
KiSC issued 12, 2006 A