Hybrid Amplifier Configurable Parameters; Hybrid Amplifier Alarm Data Parameters - Cisco Prisma II Hybrid Amplifier Installation Manual

Hybrid amplifier
Table of Contents

Advertisement

Note: Monitored values may vary from module to module. The values shown above
are examples only.

Hybrid Amplifier Configurable Parameters

Parameter
ICIM
Name (LCI)
Abbreviation
Enable Laser
Enable
Optical Power
SetAtten
Attenuation
Operational
Mode
Mode
Input Alarm
LoInpEna
Laser Shutdown
Service Mode
Service

Hybrid Amplifier Alarm Data Parameters

Parameter
ICIM
Name (LCI)
Abbrev.
Optical
InPwr
Input
Power
1
Optical
OutPwr
Output
Power
1
Laser 1
LasTemp1
Temperature
1
Laser 2
LasTemp2
Temperature
1
78-4025693-01 Rev D
Description
Enables or disables amplifier
Attenuates optical output by value
selected
Module redundancy control:
If set to Master, unit only
controlled by Enable controls
If set to Slave, unit only
controlled by external alarm
signal
Disables low input power alarms
and shuts amplifier down when
optical input level falls below -10.0
dBm
Sets optical output level to 15.0
dBm for servicing
Nominal
Major
Value
Low
Limit
-
-16
dBm
-
-1.0
dBm
25.0°C
-20.0°C
25.0°C
-35.0°C
Values
ON (1)
OFF (0)
0 to 3 dB
in 0.5 dB steps
Master (1)
Slave (0)
ON (1)
OFF (0)
ON (1)
OFF (0)
Minor
Minor
Major
Low
High
High
Limit
Limit
Limit
-5.0
25
45
dBm
dBm
dBm
-0.7
-0.7
1.0
dBm
dBm
dBm
-15.0°C
15.0°C
20.0°C
-30.0°C
45.0°C
50.0°C
Hybrid Amplifier Parameters
Default
OFF (0)
0 dB
Master
(1)
OFF (0)
OFF (0)
Hys-
Operating
teresis
Range
1.0
-
0.1
-
1.0
OK or
Alarm
1.0
OK or
Alarm
145