Config Menus; Hybrid Amplifier Service Mode - Cisco Prisma II Hybrid Amplifier Installation Manual

Hybrid amplifier
Table of Contents

Advertisement

Chapter 4 Operation Using ICIM

CONFIG Menus

When the CONFIG menu is selected, the Shelf number field is highlighted. The
shelf and slot number fields may only be incremented with the
key. The
Up and Down arrows will scroll through the parameters that are specific to this
module.
Sample CONFIG menus are shown below.
Note: For details on all configurable parameters, see Module Parameter Descriptions
(on page 143).

Hybrid Amplifier Service Mode

Service mode allows the user to reduce the output power of the module to 15 dBm
so that the optical cable connections can be made without the risk of damaging the
optical components.
The Hybrid Amplifier has multiple optical outputs that are divided into two banks.
You can change the Service mode status on all banks of optical outputs using the
Service control.
It is critical that optical connections be modified only when the module is in Service
mode. The optical output power of the module in the normal operating mode can
damage the optical components if cable connections are altered.