Hybrid Amplifier Parameters; Hybrid Amplifier Operating Status Parameters - Cisco Prisma II Hybrid Amplifier Installation Manual

Hybrid amplifier
Table of Contents

Advertisement

Appendix B
Module Parameter Descriptions

Hybrid Amplifier Parameters

Hybrid Amplifier Operating Status Parameters

Parameter
Name (LCI)
Optical Input
Power
Optical Output
Power
Laser 1
Temperature
Laser 2
Temperature
Laser 1 Bias
Current
Laser 2 Bias
Current
Laser 1 Limit
Laser 2 Limit
Laser TEC
Current
Module
Temperature
Laser On Time
Enable Laser
Optical Power
Attenuation
Operational
Mode
Input Alarm
Laser Shutdown
Service Mode
144
ICIM
Function
Abbreviation
InPwr
Displays optical input power
OutPwr
Displays optical output power
LasTemp1
Laser temperature for pump 1
LasTemp2
Laser temperature for pump 2
LasBias1
Laser bias current for pump 1
LasBias2
Laser bias current for pump 2
LasLim1
Laser bias current limit for pump 1
LasLim2
Laser bias current limit for pump 2
TecCur
Laser TecCooler current for pump 1
ModTemp
Displays module temperature
LaserOn
Displays laser ON time
Enable
Enables or disables the amplifier
SetAtten
Attenuates optical output by value
selected
Mode
Module redundancy control:
If set to Master, unit only controlled
by Enable controls
If set to Slave, unit only controlled
by external alarm signal
LoInpEna
Disables low input power alarms and
shuts down amplifier when optical input
level falls below -10.0 dBm
Service
Sets output level to 15 dBm for servicing Off
Typical
Value
5.0 dBm
19.5 dBm
25°C
25°C
0.625 A
3.25 A
0.825 A
6.25 A
0.25 A
26.5°C
1.0 Hrs
On
0 dB
Master
Off
78-4025693-01 Rev D