Cisco Prisma II Hybrid Amplifier Installation Manual page 67

Hybrid amplifier
Table of Contents

Advertisement

MODID
20/05
20/06
20/06
20/13
20/13
SUCCESS!
*/* MODULE>
Note:
The information returned by the monitor argument includes units of
measurement.
InPwr values are stated to several decimal places, but only the first 2 or 3 are
significant.
Show Alarmstate
The following sample dialog shows the kind of information returned by the
alarmstate argument.
*/* MODULE> show alarmstate *pwr <Enter>
MODID
20/05
20/06
20/06
20/07
20/08
20/13
20/13
SUCCESS!
*/* MODULE>
Note: The information returned by the alarmstate argument provides both the
numeric value and its meaning.
Show Alarmparam
Alarms also have parameters, such as thresholds. Accordingly, the alarmparam
argument is in turn followed by an argument that specifies one of five parameters:
hysteresis, majorhigh, majorlow, minorhigh, and minorlow.
78-4025693-01 Rev D
NAME
VALUE
UNITS
OutPwr
8.29224
dBm
InPwr
5.91542
dBm
OutPwr
18.9929
dBm
InPwr
17.2202
dBm
OutPwr
19.4671
dBm
NAME
STATE
OutPwr
0 (major low)
InPwr
0 (major low)
MaxInPwr
0 (ok)
OutPwr
2 (ok)
XSPwr
0 (ok)
OutPwr
0 (major low)
InPwr
0 (major low)
Module Commands
41