Displaying Temperature Messages; Changing The Temperature Warning Level; Changing The Device Temperature Polling Interval - Brocade Communications Systems Brocade TurboIron 24 Series Hardware Installation Manual

Table of Contents

Advertisement

Managing the TurboIron 24X
Managing temperature settings

Displaying temperature messages

The software sends a Syslog message and an SNMP trap if the temperature crosses the warning threshold. The following methods
describe how to view the system log on the device. If you have configured the device to use a Syslog server or SNMP trap receiver, refer
to the documentation for the server or receiver.
To display the system log, enter the following command at any CLI level.
TurboIron# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 50.0 C degrees, warning level 45.0 C degrees

Changing the temperature warning level

The default warning temperature is 45.0 C degrees. You can change the warning temperature using the temperature warning command.
The valid range is 0 - 125 C degrees.
TurboIron 24X devices automatically reset and reload the software when the internal temperature reaches or exceeds the configured
shutdown level for five minutes. The TurboIron 24X has the capability to register negative temperature settings.
To change the temperature at which the device sends a warning, enter a command such as the following at the Privileged EXEC level of
the CLI.
TurboIron# temperature warning 47
Syntax: temperature warning value
NOTE
The value can be 0 - 125.

Changing the device temperature polling interval

The software reads the temperature sensor and polls other hardware sensors according to the value set for the device poll time, which is
60 seconds by default. You can change the device poll time using the CLI.
To change the device poll time, enter a command such as the following at the global CONFIG level of the CLI.
TurboIron(config)# chassis poll-time 200
Syntax: chassis poll-time value
NOTE
The value can be 0 - 65535.
40