Managing temperature settings
FGS648P Switch#show chassis
The stack unit 1 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Current temperature : 35.5 deg-C
Warning level.......: 80.0 deg-C
Shutdown level......: 90.0 deg-C
Intake Side Temperature Readings:
Current temperature : 33.5 deg-C
Boot Prom MAC: 0012.f2de.9440
Management MAC: 0000.0000.0011
The stack unit 2 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
--More--, next page: Space, next line: Return key, quit: Control-c

Displaying temperature messages

The software sends a Syslog message and an SNMP trap if the temperature crosses the warning threshold. The following methods
describe how to view the system log on the device. If you have configured the device to use a Syslog server or SNMP trap receiver, refer
to the documentation for the server or receiver.
To display the system log, enter the following command at any CLI level. The following example is for a standalone device. To display
system logs for IronStack devices, enter the show log command for individual stack units.
FastIron#show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 50.0 C degrees, warning level 45.0 C degrees

Changing the temperature warning and shutdown levels

The default warning temperature is 45.0 C degrees. You can change the warning temperature using the following command. The valid
range is 0 – 125 C degrees.