Configuration; Setting Battery Types On The Main Unit - Xantrex Freedom HF Owner's Manual

Inverter charger
Hide thumbs Also See for Freedom HF:
Table of Contents

Advertisement

Configuration

Configuration

Setting Battery Types on the Main Unit

You can attach different types of lead-acid batteries to the
Freedom HF. Before installing batteries make sure that you
configure the unit to optimize the charging process.
The settings can be changed by adjusting the dip switches found
on the main unit behind the display panel.
Dip Switch Setting
Battery Type
Switch 1|Switch 2
Fixed
OFF|OFF
Flooded
OFF|ON (default)
GEL
ON|OFF
AGM
ON|ON
24
Bulk/Absorption
Float
13.5
13.5
14.4
13.5
14.2
13.8
14.3
13.4
To adjust the battery type setting:
1. By default the battery type is set to Flooded (OFF|ON) for all
models except Freedom HF 1800 T (806-1840-03) which is set
to AGM (ON|ON).
2. Detach the Display Panel to expose the Dip Switches.
3. Use the tip of your fingernail or a small screw driver with a flat
tip to adjust the switches.
Figure 13 Dip Switches (Default Settings Shown)
ON
OFF
Switch 1 | Switch 2
Freedom HF Owner's Guide