Environmental Requirements; Shock And Vibration Specifications; Table B-5 Environmental Requirements; Table B-6 Shock And Vibration Values - Sun Microsystems Ultra 25 Service Manual

Hide thumbs Also See for Ultra 25:
Table of Contents

Advertisement

B.4

Environmental Requirements

TABLE B-5
workstation.
TABLE B-5
Specification
Temperature
Humidity
Altitude
B.5

Shock and Vibration Specifications

TABLE B-6
TABLE B-6
Constraint
Shock
Vibration
Handling
Drop
B-4
Sun Ultra 45 and Ultra 25 Workstations Service and Diagnostics Manual • May 2006
lists environmental requirements for the Sun Ultra 45 or Ultra 25
Environmental Requirements
Operating
32 F to 104 F (0 C to 40 C)
10% to 90% RH noncondensing, 27 C
max wet bulb
10,000 ft (~3 km)
lists vibration specifications for the Sun Ultra 45 or Ultra 25 workstation.
Shock and Vibration Values
Operating
5 G's, 11 msec, half-sine
0.2 G's, 5 to 500 Hz swept-sine
N/A
Nonoperating
-40 to 158 F (-40 C to 70 C)
93% RH noncondensing
40,000 ft (~12 km)
Nonoperating
30 G's, 11 msec, half-sine
1.0 G's, 5 to 500 Hz swept-sine
100 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultra 45

Table of Contents