The following warning message example indicates that there is a DIMM size
mismatch in slots DIMM0 and DIMM1:
0>WARNING: TEST = Probe and Setup Memory
0>H/W under test = CPU0 Memory
0>MSG = DIMM size does not match for Dimm set 0, Dimm0=
00000000.40000000, Dimm1=00000000.20000000
0>END_WARNING
DIMM0 is a 1-GByte DIMM and DIMM1 is a 512-MByte DIMM.
11.4.3

Info Messages

Info messages are simple and are only preceded by the text, INFO. Info messages
provide noncritical facts, as seen in this example:
0>Probe and Setup Memory
0>INFO: 1024MB Bank 0, Dimm Type X4
0>INFO: 1024MB Bank 1, Dimm Type X4
0>INFO: 1024MB Bank 2, Dimm Type X4
0>INFO: 1024MB Bank 3, Dimm Type X4
These info messages indicate that a 1-GByte DIMM is installed into each DIMM
connector.
11.5

Setting Up for POST

To execute POST and view its output, you must perform the procedures in the
following sections.
11.5.1

Verifying the Baud Rate

Ensure that the communication parameters are correct. Use one of the following
procedures: