Setting Baud Rate - Dalsa Spyder 3 GigE SG-10-01k80-00-R User Manual

Dual line scan camera
Table of Contents

Advertisement

Spyder 3 GigE User's Manual

Setting Baud Rate

Purpose:
Syntax:
Syntax Elements:
Notes:
Example:
Camera ASCII Command Help
For quick help, the camera can return all available commands and parameters through
the serial interface.
There are two different help screens available. One lists all of the available commands to
configure camera operation. The other help screen lists all of the commands available for
retrieving camera parameters (these are called "get" commands).
To view the help screen listing all of the camera configuration commands, use the command:
Syntax:
To view a help screen listing all of the "get" commands, use the command:
Syntax:
Notes:
The camera configuration command help screen lists all commands available. Parameter
ranges displayed are the extreme ranges available. Depending on the current camera
operating conditions, you may not be able to obtain these values. If this occurs, values are
clipped and the camera returns a warning message.
Some commands may not be available in your current operating mode. The help screen
displays NA in this case.
DALSA
Sets the speed in bps of the serial communication port.
sbr m
m
Baud rate. Available baud rates are: 9600 (Default), 19200 ,
57600 , and 115200 .
Power-on rate is always 9600 baud.
The
(reset camera) command will not reset the camera to
r c
1 3 H
the power-on baud rate and will reboot using the last used
baud rate.
sbr 57600
h
gh
For more information on the camera's "get" commands, refer to
section
A 4.7 Returning Camera Settings.
2 8 2 H
55
03-032-10158-09

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents