3.6 Setting Baud Rate

To set the speed of the camera serial communication port, use the command:
Syntax:
Syntax Elements:
N otes:
Example:

3.7 Setting the Data Mode

To select the camera output mode, use the command:
Syntax:
Syntax Elements:
N otes:
Example:

3.8 Setting the Video Mode

The video mode sets w hether the camera is running in calibrated or uncalibrated mode,
or if it is generating a test pattern.
To set the video mode, use the command:
Syntax:
Syntax Elements:
N otes:
Example
03-032-10091-06
sbr i
i
Baud rate. A vailable baud rates are: 9600 (Default), 19200,
57600, and 115200.
Pow er-on rate is alw ays 9600 baud.
The rc (reset camera) command w ill not reset the camera to
the pow er-on baud rate.
sbr 57600
sdm i
i
0 8-bit, using port A for single processor configuration
1 10-bit, using ports A and B for single processor configuration
To obtain the current data mode, use the command gcp.
sdm 0
svm i
i
Video mode to use. A llow able values are:
0 Uncalibrated video, deactivated video correction
1 Calibrated video, activated video correction
2 Test pattern right
To obtain the current video mode, use the command
svm 1