6) When aperture grille get entangled while degaussing, receive the signal of 1dot alternate pattern and
degauss again. If aperture grille remain entangled, vibrate from side.
5. Signal Generator
LVG-1603 is recommended for signal generator.
Use calibrated signal generators. However, use VG-819 in focus regulation.
Note) Adjustment timings are timing tables and are not programmed timing.
6. Color Analyzer, Convergence Meter, Landing Mater
The color analyzer should be CA-100 (made by MINOLTA) or compatible.
The convergence meter should be CC-100 (made by MINOLTA) or compatible.
The Landing meter should be KLD-01 (made by KAMAYA) or compatible.
7. OSM Menu Operation
7-1. Front Panel
EXIT
7-2. OSM Menu
This unit is adjusted in on screen menu by front panel key operation.
There are 2 types of On Screen menu.
1) Menu (user): This Menu can be operated by a customer.
2) Menu (service): This Menu is hidden from a customer.
Here after, they will be called MENU (U) and MENU (S).
The menu can be displayed when the signal is input to the display unit.
7-3. FACTORY MODE
This model has function that is named "FACTORY MODE"
When the FACTORY MODE is
ON: LED indicator light is yellow usual. But when TAG 3, TAG 4, TAG 5, TAG B or TAG C is selected, LED
indicator light is orange.
Power management function does not work.
It is possible to enter MENU (S) by shortcut key.
OFF: LED indicator is GREEN when Horizontal and Vertical Sync Pulse are ON.
Power management function works when the Horizontal or (and) Vertical sync are OFF. It is not
possible to enter MENU (S) by shortcut key.
Always turn on "FACTORY MODE", when adjust the monitor.
If the adjustment finish, should be "FACTORY MODE" OFF.