Function of each key is as follows
"1"
"4"
"7"
"3"
"6"
"9"
"5"
"e or E" : ends without saving data
"ENTER" : Ends after saved data
b-6. Return to Size / Position adjustment menu by pushing "e" key, and select "5 : H. SIZE(MAX)".
b-7. If adjustment is ended, push "RETURN" key to end the adjustment.
(H. SIZE MAX data values of all preset signals are written by this operation.)
b-8. Select "84: H_MAX2" on the menu D, repeat steps b-4 to b-7.
c. V. SIZE(MAX) adjustment
c-1. Open menu D, "85 : V. SIZE(MAX)" and push "RETURN" key.
c-2. Input a signal displayed on the screen. ( If signal is not displayed on the screen, use a signal
indicated vertical maximum size adjustment section in the service manual. )
c-3. As following message will appear on screen, push "RETURN" key.
"INPUT V. SIZE(MAX) SIGNAL HIT ENTER KEY"
c-4. Following menu G will appear on screen.
INPUT V. SIZE(MAX) SIGNAL HIT ENTER KEY
DAC VALUE :
Decrease : 1(-1), 4(-5), 7(-10) Increase : 3(+1), 6(+5), 9(+10) Original : 5
END(NO WRITE) : e E
c-5. Adjust a vertical maximum size value as indicated on the service manual.
c-6. If adjustment is ended, push "RETURN" key to end the adjustment.
: data value decreases by 1 (H. SIZE becomes smaller)
: data value decreases by 5 (H. SIZE becomes smaller)
: data value decreases by 10 (H. SIZE becomes smaller)
: data value increases by 1 (H. SIZE expands)
: data value increases by 5 (H. SIZE expands)
: data value increases by 10 (H. SIZE expands)
: set up data value to reference value
0
END(WRITE) : ENTER
Adjust the horizontal size to horizontal maximum size
adjustment value on service manual.
(Menu G)