Window Removal
1. Turn the top two spring-loaded window bolts through 90 degrees to release
the window from the fi rebox.
2. Remove the bottom two spring-loaded window bolts.
3. Carefully lift the window away. Keep the window and bolts in a safe place.
Rear Vent Outlet Positioning
If installing with top vent outlet, ignore this stage.
If installing co-linear venting, see instructions supplied with the co-linear
adapter.
1. Remove the rear outlet cover plate and seal by unscrewing 12 screws. Keep
the seal and plate for fi tting to the top.
2. Remove the top outer vent collar and seal by unscrewing 12 screws.
3. Remove the top inner vent collar and seal by unscrewing 8 screws.
4. Locate the inner collar and seal inside the rear outlet opening. Secure the
inner collar with 8 screws.
5. Fit the outer collar over inner collar. Loosely fi t the 12 screws. Place the
adapter 817VAK or Valor terminal kit 551DVK over the collars to check
alignment. Tighten the 12 screws to secure the outer collar.
6. Fit the cover plate and seal (removed from the rear) to the top vent opening
with 12 screws.
817VAK Vent Adapter Fitting
If rear venting with Valor terminal unit 551DVK, ignore this stage.
1. Fit the adapter 817VAK over the appliance vent collars pushing on fi rmly.
2. For rear vent outlet connection, align the adapter so that the seam on
horizontal pipes is not at the bottom—check by temporarily fi tting a pipe.
3. Drill through the adapter outer tube and appliance outer collar for no. 6
screws. Make sure that the drill does not penetrate the inner tubes.
4. Secure the adapter to the outer collar with two no. 6 thread-cutting screws
supplied.