Specifi Cations - Valor Horizon 534ILN Installation And Operation Instructions Manual

Natural / propane gas direct vent gas fireplace heater
Table of Contents

Advertisement

Approvals & codes
These appliances are certifi ed by ANSI Z21.88-2009/CSA
2.33-2009 American National Standard / CSA Standard
for Vented Gas Fireplace Heaters for use in Canada and
USA. These appliances are for installation directly venting
through an outside wall or through the roof.
Model 534ILN is for use with natural gas.
Model 534ILP is for use with propane gas.
Conversion between fuels may only be done using the
approved conversion kits listed in the section Options.
These appliances comply with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform with local codes or, in
the absence of local codes with the National Fuel Gas
Code, ANSI Z223.1 or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only qualifi ed
licensed or trained personnel should install these
appliances.
These appliances, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)
Input Max. (Btu/h)
Input Min. (Btu/h)
Manifold pressure (in w.c..)
Min. Supply pressure (in. w.c.)
Max. Supply pressure (in. w.c.)
*Tested to CGA - 2.17-91 High Altitude Standard in
Canada. In the USA, installations may require deration
over 2000 feet—check local codes.
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Specifi cations
Supply Gas
Heater engine unit 534ILN is used with natural gas
installations.
Heater engine unit 534ILP is used with propane gas
installations.
The supply pressure must
be between the limits shown
in the table above.
The supply connection is ⅜
inch NPT.
The opening for the gas
supply line is at the left side
of the appliance.
Wall Thickness
The vent system (when horizontally terminated) is
approved to pass through combustible wall construction of
up to 14 inches (36 cm) thick.
A non-combustible wall can be any thickness up to the
maximum horizontal run of vent pipe allowed for the
particular installation—see Venting section.
Venting options
Direct vent installations (solid piping)
534ILN
534ILP
A list of all approved venting accessories is shown on
pages 37–38 of this manual.
Natural
Propane
NOTE: An 817VAK Vent Adapter is required in all cases
0-4500 *
when using vent components other than Valor's 551DVK
24,000
24,000
Standard Vent Terminal.
6,500
13,000
Direct Vent Co-Linear Installations (fl exible piping)
3.95
10.5
Converts the appliance outlet collars to accept two 3-inch
5.0
11.0
diameter fl ex liners for installation into existing solid-fuel
11.0
14.0
burning fi replaces and chimneys. Requires a co-linear
adapter at the appliance and either a co-linear terminal or
co-linear-to-co-axial adapter and terminal at the top of the
chimney. A list of approved venting accessories is shown
on pages 37–38 of this manual.
Floor/Hearth
This appliance is approved for installation directly on
combustible material such as plywood and so on. Vinyl,
carpet, and soft fl ooring require sheet metal extending the
whole width and depth under the appliance.
This appliance does not require a hearth. Combustible
fl ooring may extend up to the front of the unit.
X
X
7 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon 534ilp

Table of Contents