Valor Horizon 534ILN Installation And Operation Instructions Manual page 21

Natural / propane gas direct vent gas fireplace heater
Table of Contents

Advertisement

Air Restrictors Fitting
No restrictors are required for appliances which only have a
horizontal vent run. If installing an appliance which has a rear vent
outlet connection and no vertical vent pipe rise, ignore this stage.
A restrictor set, shown right, is supplied with each 534 engine unit. The
restrictors cover part of the inlet air openings in the fi rebox rear wall
behind the rear log support.
The restrictor is assembled with an adjustable piece which can be moved
to different positions depending of the vent confi guration. See the table
below to fi nd out which position is optimal for each type of installation.
• To fi t the restrictors, loosen the two center screws of the left and right
inlet ports. Place the restrictor assembly under the screw heads and
tighten the center screws.
• To set the adjustable restrictor piece, loosen the two screws, position the
adjustable piece according to the diagram below and tighten the screws.
Appliance
Vent terminal
vent outlet
Horizontal
Top
through wall
with vertical
rise
Appliance Preparation
Vertical vent
Use restrictor
pipe run
setting
Less than
3' (91 cm) to
6' (183 cm)
From
6' (1.83 m) to
20' (6.1 m)
From
20' (6.1 m) to
40' (12.2 m)
Air Restrictor Assembly
Appliance
Vertical vent
Vent terminal
vent outlet
Horizontal
Rear
Less than
through wall
3'6" (107 cm)
with vertical
to 6' (183 cm)
rise
From
6' (1.83 m) to
20' (6.1 m)
From
20' (6.1 m) to
40' (12.2 m)
Appliance
Vertical vent
Vent terminal
vent outlet
Vertical
Top or rear
Less than
through roof
20' (6.1 m)
From
20' (6.1 m) to
40' (12.2 m)
Use restrictor
pipe run
setting
Use restrictor
pipe run
setting
Adjustable
piece
21
21