Location; Venting - Valor Horizon 534ILN Installation And Operation Instructions Manual

Natural / propane gas direct vent gas fireplace heater
Table of Contents

Advertisement

Vent Material
This unit is approved for installation using 4 x 6-5/8
inches approved co-axial direct vent pipes and acces-
sories listed on pages 37–38 of this guide. Follow the
installation instructions supplied with the individual
venting accessories.
This unit may also be converted to co-linear venting
with two 3-inch pipes for use in solid-fuel burning
fi replaces and chimneys using approved adapters and
accessories listed on pages 37–38 of this guide.
Wall Thickness
The appliance vent is suitable for penetrating a
combustible wall assembly up to 14 inches in
thickness. A non-combustible wall can be of any
thickness up to the maximum horizontal run of vent
pipe allowed for the particular installation.

Location

Venting

Vent Penetration through Walls & Ceilings
Combustible: When penetrating through combustible
walls and ceilings, frame a minimum of 10 inch x 10
inch opening and ensure that the insulation is kept
clear of the vent pipe using either a wall thimble
or an attic insulation shield. Follow the installation
instructions supplied with the individual venting
components.
Non-combustible: If the wall is totally non-combustible
(e.g. masonry block or concrete), mark for a 7 inch
circular hole.
In both cases, the center of the hole should line up with
the center line of the horizontal vent.
Align the vent
center to the
center of the
frame
10" (254 mm)
Square opening
10" (254 mm)
11 11