Operation Check & Aeration Settings Adjustment
Operation Check
Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 31–34.
Aeration Settings
Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. Burners are
equipped with an adjustable shutter to control primary
aeration. See the fi gures below. The shutter is
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
Air Shutter
NG Air Shutter
Slider & Cover

Remote Control Handset Wall Holder Installation

The remote control kit for this fi replace comes
complete with a wall-mounted holder. This
holder is not required in all installations but
is provided as an optional feature for those
customers who wish to mount the remote
handset to the wall.
To install the holder to the wall, fi nd a
convenient location and use the hardware
provided with the kit. See the diagram on the
right for required hardware and confi gurations.
Note that the holder can be installed at the base
of a light switch plate.
IMPORTANT. The location of the remote
control handset is important to assure proper temperature regulation. To obtain a constant
temperature, we recommend that the handset should be between 3 and 15 feet away from the
appliance but not directly above it. We also advise that the handset should be located away
from any other heat source and not in direct sunlight as this may affect the temperature sensor
located in the remote handset.
NG
Close
Open
Close
Open
1 Wall Bracket A
2 Screws B
1 Screw C
2 Wall Anchor D
1 Spacer E
(detach before assembly)
1 Wall Bracket F
In a few unusual installations, the fl ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the ceramic rocks and window installed.
Increasing aeration will cause the fl ames to appear
more transparent and blue showing more ceramic rock
glow.
Decreasing aeration will cause the fl ames to appear
more yellow or orange showing less ceramic rock glow.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
Flashback
shield (for
LPG only)
LPG Air Shutter
Slider
Alternative 2
Packing Contents:
Alternative 1
LPG
Close
Open
Alternative 3
Switch Plate
27