Location And Mounting - Ametek SPS A Series Operation Manual

Ametek sps a series dc power supplies
Table of Contents

Advertisement

Installation
Bolt, lock washer, and nut for output power connections:
20–30 kW: 3/8-16UNC-2B x 1/4", 4 ea for AC input
Black screw, 10-32UNC-2B x ½", front panel rack fastener:
5–15 kW (40-800V): 4 ea
4-15Kw (10-30v): 1/2-13UNC-2B x 1.5" long, 4 ea
20–30 kW: 8 ea
Note: If any of these parts are missing, please contact Customer Service
at 858-458-0223 (local) or 1-800-733-5427 (toll free).

LOCATION AND MOUNTING

2.3
WARNING!
To reduce the risk of fire or electrical shock, install the SPS-A Series unit in a
temperature and humidity controlled indoor area, free of conductive contaminants.
CAUTION!
The unit should be provided with proper ventilation. The rear and both sides of the
unit should be free of obstructions. To ensure proper airflow, a minimum 4"
clearance from the rear air outlet is required. The unit should not be installed in a
raised ambient temperature greater than 50°C.
CAUTION!
This unit is intended for installation in a protected environment. No user
serviceable parts inside. Service to be performed by qualified personnel only.
CAUTION!
Ensure that the concentration of ozone is limited to a safe value. The
recommended long-term exposure limit for ozone is 0.1 PPM (0.2 mg/m
BURN HAZARD!
Hot Surface Warning. Allow to cool before servicing.
Please refer to sections 2.7 and 2.8 for dimensional and installation
drawings.
1-2
3/8-16UNC-2B x 3/8", 2 ea for DC output
AMREL SPS-A Series
3
).
M550129-01 Rev A