LOAD CONSIDERATIONS

2.6
This section provides guidelines for using properly rated diodes to protect
the power supply from damage while driving inductive loads.

2.6.1 INDUCTIVE LOADS

To prevent damage to the power supply from inductive kickback, connect
a diode (rated at greater than the supply's output voltage and current)
across the output. Connect the cathode to the positive output and the
anode to return. Where positive load transients such as back EMF from a
motor may occur, a second diode in series with the output is
recommended to protect the power supply.
B
LOCKING AND
The Peak Reverse Voltage ratings should be a minimum of 2-3 times the
Power Supply maximum output voltage. The Continuous Forward Current
ratings should be a minimum of 1.5 times the Power Supply maximum
output current. Heatsink may be required. There also may be a need for
higher voltage rated parts, dependent on load circuit design and inductor
values.

OUTLINE DRAWINGS

2.7
Figure 2-2 and Figure 2-3, next, show the outlines and overall dimensions
of the 3U and 6U models of the SPS-A Series product line. Figure 2-4,
Figure 2-6, Figure 2-7, and Figure 2-9 provide detailed information for
installation purposes.