Analog Control Connector (J1); Figure 3-8. Analog Control Connector (J1) Pin-Out - Ametek SPS A Series Operation Manual

Ametek sps a series dc power supplies
Table of Contents

Advertisement

AMREL SPS-A Series

3.3.6 ANALOG CONTROL CONNECTOR (J1)

The ANALOG CONTROL connector on the rear panel allows the unit to
be configured for different operating configurations: local and remote
current programming, local and remote voltage programming, current and
voltage output monitoring, output enable/disable, etc. The setup and
operating requirements of each configuration are provided in Sections 3.4
through 3.9.
I
SOLATED
The Isolated Analog Control uses the same Analog Control connector
(J1). This option fully isolates remote control signals and allows control of
units not connected to a common ground. Control ground is isolated from
power ground, which protects against potential damage from systems
with high electrical noise or large ground loop currents.
Note: Some standard analog programming signals may not be available
with this option. See Table 1.2.2 for details.
CAUTION!
This option is not intended to allow operation of the power supply at
excessive voltages. Refer to Section 2 INSTALLATION for maximum
terminal voltages.
Following are Figure 3-8 with the connector's pin-out diagram, and Table
3–1 with ANALOG CONTROL connector designations and functions:

Figure 3-8. ANALOG CONTROL Connector (J1) Pin-out

M550129-01 Rev A
A
C
(O
NALOG
ONTROL
)
PTION
Operation
3-13

Hide quick links: