HP Z600 Maintenance And Service Manual page 195

Hide thumbs Also See for Z600:
Table of Contents

Advertisement

Table 6-10
POST error messages (continued)
Screen message
164—Memory Size Error
201—Memory Error
202—Memory Type Mismatch
203—Memory module failed
self-test and failing rank was
disabled
204—Memory module failed
and user rank was disabled
205—Memory high
temperature detected
206—Memory setup invalid
207—Incompatible DIMMs
detected
208—Mismatched DIMMs
detected
209—Memory warning
condition detected
212—Failed Processor 0
213—Incompatible Memory
Modules
214—DIMM Configuration
Warning
ENWW
Probable cause
Memory configuration is incorrect.
RAM failure.
Memory modules do not match.
Defective memory module.
Improper module load.
Insufficient memory module cooling.
Memory configured incorrectly.
DIMMs are installed that do not fulfill
system requirements.
Installed DIMMs are improperly
matched.
Incorrect memory module type in use.
Processor has failed to initialize.
A memory module in the memory
socket identified in the error message
is missing critical SPD information, or
is incompatible with the chipset.
DIMMs are not installed correctly (not
paired correctly).
Recommended action
1.
Run the Computer Setup (F10) Utility or the
Windows utilities.
2.
Verify that the memory modules are installed
properly.
3.
If third-party memory has been added, test the
memory configuration using HP memory.
4.
Verify the memory module type.
1.
Run the Computer Setup (F10) utility or Windows
operating system utilities.
2.
Be sure that memory and continuity modules are
installed correctly.
3.
Verify the memory module type.
4.
Remove and replace memory modules one at a
time to isolate faulty modules.
5.
Replace faulty memory modules.
6.
If the error persists after replacing memory
modules, replace the system board.
Replace the memory modules with matched sets.
Replace the memory module.
Reseat the memory module correctly.
Verify that a memory module cooling fan is installed and
operating.
Reconfigure the memory modules in the proper slots.
1.
Verify that the memory module type matches
workstation requirements.
2.
Insert the DIMM in the proper memory socket.
3.
Replace the DIMM if the problem persists.
Verify that matching DIMMs are installed.
Verify that the memory modules are compatible with
workstation requirements.
1.
Reseat the processor in its socket.
2.
If the processor does not respond, replace it.
1.
Verify the memory module type.
2.
Insert the DIMM in another memory socket.
3.
Replace the module with a DIM conforming to the
SPD standard.
See the service label on the workstation access panel
for the correct memory configurations, and reseat the
DIMMs accordingly.
Diagnostic codes and errors 183

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Z600 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents