Table 6-10
POST error messages (continued)
Screen message
215—DIMM Configuration
Error
216—Memory Size Exceeds
Maximum Supported
301—Keyboard Error
303—Keyboard Controller
Error
304—Keyboard or System
Unit Error
510—Splash Screen image
corrupted
511—CPU. CPU A, or CPU B
Fan not detected
512—Rear Chassis fan not
detected
513—Front Chassis fan not
detected
514—Memory fan not
detected
515—CPU Overtemp ocurrred Insufficient processor cooling or
516—Chipset fan not detected Chipset fan missing, disconnected, or
517—Low power CPU
heatsink(s) detected for high
power CPUs
184 Chapter 6 Diagnostics and troubleshooting
Probable cause
The amount of memory installed
exceeds that supported by the
hardware.
Keyboard failure.
I/O board keyboard controller is
defective or is not set properly.
Keyboard failure.
Splash Screen image has errors.
Fan is not connected or is defective.
Rear fan missing, disconnected, or
defective.
Front fan missing, disconnected, or
defective.
Memory fan missing, disconnected, or
defective.
processor defect.
defective.
Inadequate heatsink is installed.
Recommended action
1.
Verify how much memory the workstation
supports.
2.
Remove the excess memory.
1.
Reconnect the keyboard with the workstation
powered off.
2.
Check the connector for bent or missing pins.
3.
Be sure that none of the keys are pressed.
4.
Replace the keyboard.
1.
Reconnect the keyboard with the workstation
powered off.
2.
Replace the system board.
1.
Reconnect the keyboard with the workstation
powered off.
2.
Be sure that none of the keys are pressed.
3.
Replace keyboard.
4.
Replace system board.
Update system BIOS.
1.
Reseat the fan cable.
2.
Reseat the fan.
3.
Replace the fan.
1.
Reseat the fan cable.
2.
Reseat the fan.
3.
Replace the fan.
1.
Reseat the fan cable.
2.
Reseat the fan.
3.
Replace the fan.
1.
Verify that the memory fan is installed and
connected properly.
2.
Replace the fan.
1.
If necessary, add a heatsink to the processor and
ensure proper operation.
2.
Replace the processor.
1.
Ensure that the fan is installed and connected
properly.
2.
Replace the fan.
Replace the low power heatsink with a high power
heatsink.