CONNECT VENT SYSTEM TO AIR DUCT

1.
Place air duct (previously removed from insert top, page 14)
into the existing fireplace opening.
2.
Place a bead of sealant (provided) around 3" exhaust pipe
(red marking). Slide exhaust pipe inside 3" collar marked
„Exhaust‟ on the air duct. Secure with (3) ½" self-tapping
screws, provided. Apply additional sealant around the joint
to ensure an air-tight seal.
3.
Apply a liberal bead of sealant (provided) around 3" collar
on the air duct. Slide 3" combustion intake pipe over the
collar. Secure with (3) ½" self-tapping screws, provided. To
ensure an air-tight seal, apply additional sealant around the
joint.

POSITION FIREPLACE INSERT

1.
Slide insert into fireplace opening.
2.
Position air duct into channels located at top of insert. Slide air duct forward until seated.
3.
Secure air duct to insert front with (2) 1/2" sheet
metal screws (included in components packet).
Secure with sheet metal screws
Shown without venting attached
for clarity purposes only
4.
If necessary, level insert by threading leveling bolts (included
in components packet) into nuts mounted in the bottom of
insert behind lower air passage - 2 each side.
PAGE 17
Sheet metal screws
(3 total)
Leveling legs (2 per side)