Shutdown Instructions; Start Up Test Procedure Gas Gemini - Cleveland 24CGA10.2 Installation And Maintenance Instructions Manual

Dual gas steam generator & convection steamer
Hide thumbs Also See for 24CGA10.2:
Table of Contents

Advertisement

b) After 2 to 3 minutes, water reaches the middle probe (safety level).
c) Turn on a cooking compartment (for non-"Instant ON" units only) and the burners will light
with a distinctive sound. NOTE: Cooking compartment doors must be closed first.
¨ If the burners light within 5 minutes of turning the unit ON, the ignition controls are
functioning normally. End this test procedure here.
¨ If the burners do not light within 7 minutes, there may be air in the gas supply lines
proceed to step 5.
5). Turn off electrical power to the Steamer, at both the ON/OFF levers/switches and the main
power switch.
NOTE:
6). Wait 5 minutes and then repeat steps 2 through 6. If this is a brand new installation, or an
excessive amount of air in the lines is suspected for any other reason, it may be necessary to
bleed the excess air from the lines. This should be done at a union or connection as close as
possible to the inlet of the automatic gas valve.
7). If the burner does not light after the third attempt, call a Cleveland Range authorized service
representative to adjust the burner controls.
8). Go to Shutdown Instructions.
b. Shutdown Instructions
1). Turn off electrical power to the steamer, at both the ON/OFF levers/switches and the main
power switch.
2). Turn off gas supply at the main manual gas valve.

3. Start up Test Procedure Gas Gemini

Cleveland Range steamers have either a manual dial timer control panel, an electronic control panel with a
keypad timer control, an "Instant ON" control system (available only for the Gemini 6 pan model) or an
ON/OFF control panel. There are a few operating differences between steamers with the dial timer controls
and steamers with the keypad controls.
The differences in cooking operation of the two types of timer controls are fully explained in the separate
OPERATORS MANUAL. The "Instant ON" model has no operating controls other than the Power ON/OFF
lever, and begins heating to produce steam as soon as the ON/OFF lever is set to the ON position. The
ON/OFF Control Panel, operates exactly like the manual operation of the timed models except a selector
switch is used to turn the steam to the cooking compartments ON and OFF. After performing the startup
procedure, perform the test procedure as appropriate to the control panel on the steamer being tested.
Ignore any steps, which do not apply to the steamer being tested.
This procedure is appropriate for steamers with keypad control panels, dial timer control panels, "Instant
ON" or manual control panels. Read through all steps of this procedure before starting. Complete the startup
procedure before starting the actual operating tests. This procedure should be performed only by a
service technician or installer.
NOTE: Each compartment has its own steam generator and control system, and must be started
independently.
When the burners fail to ignite, a safety circuit in the igniter control de-energizes
the system and closes the automatic gas valve. The safety circuit resets when
the steamer's power is turned OFF and then back ON.