Test Water Supply Lines; Electric Connections For The Steamchef - Cleveland SteamChef 22CGT3 Installation Manual

Steam cooker and rethermalization unit
Hide thumbs Also See for SteamChef 22CGT3:
Table of Contents

Advertisement

SteamChef
Condenser
Water Reservoir
Figure 3-5 Cleveland Range Single Water Supply Arrangement
SteamChef
Condenser
Water Reservoir
Figure 3-6 Cleveland Range Separate Water Supply Arrangement
"Conditioned" indicates water that has been filtered or treated by a Cleveland Range approved method
to meet or exceed the water quality standards in the Warranty.

3. Test Water Supply Lines

a. Make sure the Main External Power Switch is OFF.
b. Check all connections for proper tightness.
c. Remove the control side panel to inspect water connections inside the SteamChef.
d. Open the water supply valves.
e. Check all lines and connections for leaks, both inside and outside the SteamChef.
f.
Correct any leaks.
g. Replace the side panel and secure it to the SteamChef before starting the SteamChef.
G. Electric Connections for the SteamChef
1. Check the rating plate to make sure the SteamChef is compatible with the local electric supply.
The rating plate is located on the side panel OPPOSITE the control side.
The electrical diagram and the spare parts list are on the side panel on the control side.
The main terminals are behind the control side panel in the service connection area.
2. The electrical supply must match all electrical and wiring requirements specified on the rating plate and
the connection must be made in accordance with the following requirements:
a. The SteamChef must be properly grounded by the installer.
b. The electrical power lines must be installed in accordance with:
The National Electric Code, ANSI/NFPA No. 70 LATEST EDITION (USA).
Canadian Electrical Code, CSA C22.2.
Any other applicable national, state, or local laws, codes, and regulations.
3. A main external disconnect switch should be installed near the SteamChef as shown in Figure 3-7.
A separate fuse or breaker sized to meet the line amps required by the SteamChef should be
installed either as part of the main external power switch or in a separate fuse box.
Filter
Check Valve
Washer
Pressure Reducer
(if required)
Check Valve
Filter
Washer
Pressure Reducer
(if required)
9
Air/Water Column
(if required)
Main Cold
Water Supply
Main Water
Shut Off Valve
Air/Water Column
(if required)
Standard Cold
Water Supply
Main Water
Shut Off Valve
Conditioned Cold
Water Supply*