I-Class Mark II Maintenance Manual
Advanced Entry Calibration (continued)
Step
Action
Use the buttons to set the Gain
Number determined in the
L
previous step. Press ENTER to
enable the setting.
Complete a table (see example
below) using new measurements,
as follows:
(A) Raise the Printhead Assembly.
Place the label over the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as P.
(B) Raise the Printhead Assembly.
M
Place the liner, notch, or mark
over the Media Sensor then lower
and latch the Printhead Assembly.
Record the sensor reading as G (or
M).
(C) Raise the Printhead Assembly.
Remove all media from the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as E.
Gain Number
Displayed Message
TRAN SENSOR GAIN
yyy
TRAN SENSOR GAIN
yyy
Paper
18
173
Adjustments and Maintenance
(0 - 31)
18
(0 - 31)
18
Selected Gain Table
Gap (or Mark)
42
10
Comment
This example uses Gain Number
18.
Where "yyy" is a numerical value
representing the current sensor
reading.
 The re-sampled values may
differ from those previously
noted. This is normal; do not
readjust the Media Sensor.
Empty