I-Class Mark II Maintenance Manual
Advanced Entry Calibration (continued)
Step
Action
Use the buttons to increment the
Gain Number by one. Record the
J
TOF Value. Repeat this process for
each Gain Number.
Gain Number
Step
Action
In your sample calibration table,
where both the Label Value and
TOF Value are at least 20, subtract
the amounts and record the result
as a Difference Value (see below).
K
Identify the largest Difference
Value and the corresponding Gain
Number. This Gain Number will be
used to resample the media.
Gain Number
Displayed Message
TRAN SENSOR GAIN
yyy
Sample Calibration Table
Label Value
00
252
01
250
02
248
...
...
31
09
Displayed Message
TRAN SENSOR GAIN
yyy
Sample Calibration Table
Label Value
00
252
01
250
02
248
...
...
15
188
16
184
17
179
18
174
19
170
...
...
31
132
Adjustments and Maintenance
These are TOF Values, where
"yyy" represents the current
(0 - 31)
sensor reading.
01
TOF Value
248
245
234
...
14
In this example, Gain Number 18
is chosen because, where both
(0 - 31)
values are at least twenty, it has
31
the highest Difference Value.
TOF Value
248
245
234
...
63
51
38
25
19
...
14
9
Comment
Difference Value
Comment
Difference Value
4
5
14
...
125
133
141
149
N/A
...
N/A