3. Use the ▲ or ▼ key to select Buttons and press ENTER.
4. Use the ▲ or ▼ key to select Auto and press ENTER to toggle between [Align only] and [Auto-image menu].
Image 13-47

13.7.3 Over temperature DMD safety

What can be done
When the temperature of the DMD becomes higher than the normal operation temperature (between 60 and 64 °C) it is possible to
switch the lamp mode of the projector automatically from 4 lamps to 2 lamps so that the DMD temperature can cool down. A warning
remains on the local LCD panel and the warning LED is on as long as the temperature is too high. When the temperature exceeds
64°C then the projector is switched to standby and an error is displayed on the LCD panel.
How to configure the over temperature safety
1. Press MENU to activate the menus.
2. Use the ▲ or ▼ key to select Projector control and press ENTER.
3. Use the ▲ or ▼ key to select Buttons and press ENTER.
4. Use the ▲ or ▼ key to select Overtemp DMD and press ENTER to toggle between [On] and [Off].
On
When temperature is too high, lamp mode is switched from 4 to 2 lamps. The 4 lamps mode can only be restored
after switching first to standby and restarting the projector.
If the temperature exceeds 64 °C, the projector is switched to standby.
Off
for a temperature between 60 and 64 °C the projector continues in normal operation but the warning is set on the
LCD display. Once the temperature is higher then 64 °C, then the projector is switched to standby.
Image 13-50

13.8 Menu position

What is possible?
The on screen menu and the bar scale can be positioned on different places on the screen.