Barco CLM HD8 R9050130 User Manual page 178

Hide thumbs Also See for CLM HD8 R9050130:
Table of Contents

Advertisement

D. Troubleshooting
Error
Description
code
2005
Lamp stop
failed
2100
LPS 1 error
2400
LPS 2 error
2700
LPS 3 error
3000
LPS 4 error
3899
Spi flash
invalid type
3898
Spi flash busy
3999
IR buffer full
4000
Incompatible
hardware
4199
FIB reset
failed
4198
FPGA PMP
init failed
6099
Board ID
unkown
version
6098
Board ID
invalid string
7999
DMD temp low
7998
DMD temp
high
7997
Ambient temp
low
7996
Ambient temp
high
7994
TEC temp
high
7992
LPS1 temp
high
7990
LPS2 temp
high
7988
LPS3 temp
high
174
Error
Warn-
Caused by
ing
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
Yes
Yes
Yes
Yes
No
Incompatible hardware used
-
Yes
no communication with FIB
-
Yes
Yes
Yes
Yes
Yes
Low temperature on DMD
Yes
Yes
High temperature on DMD
Yes
Yes
Ambient temperature out of
specifications
Yes
Yes
Ambient temperature out of
specifications
Yes
Yes
Yes
Yes
High temperature on LPS1
Yes
Yes
High temperature on LPS2
Yes
Yes
High temperature on LPS3
Action
Call qualified service engineer
Replace LPS
Replace LPS
Replace LPS
Replace LPS
Change to correct hardware
Call a qualified service engineer
turning on the lamp(s) will heat up
the DMD
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
take measurements to increase the
temperature
check ambient conditions
check if air slots are free, clean air
filter.
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
R59770057 CLM HD8 16/07/2007

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clm hd8 r90501301Clm hd8

Table of Contents