12. Alignment menu
Image 12-47
2. Enter value for horizontal active as follows :
Horz. active= [(Horz. resolution of 1 projector)/(Total horz. screen resolution)] x (horz. resolution source)
3. Horizontal start = original start + [(Horz. resolution source) minus (newly calculated Horz. active)]
Example
Horizontal resolution source : 1600 pixels
horizontal resolution projector 1 & 2 : 1024 pixels
Overlap : 100 pixels
Total horizontal screen size in pixels : 1948 pixels
Horz; active projector 1 = [(1024 / 1948)] x 1600 = 841 pixels
Horz. active projector 2 = [(1024 / 1948)] x 1600 = 841 pixels
Horz. start projector 2 = Horz. start projector 1 + (1600 – 841)

12.11.6 ScenergiX overlap zone (vertical ScenergiX)

Definitions
Image 12-50
Scenergix overlap zone vertical
Overlap : number of pixels that overlap
Vertical resolution of 1 projector : 768 for Graphics versions, 1024 for Reality versions, 1050 for SXGA projectors.
Total vertical screen resolution : [(Vertical resolution of 1 projector) x 2] minus (overlap)
Vertical Resolution source : number of active lines of the source
Adjustment of Active lines (Lact) of the first projector
1. Go to Image –> Timings menu of first projector.