Installation Procedures: 12" and 15" Panels
Drywall/
sheetrock
Mounting tabs
for NXD panel should
be flush with the outside of the sheetrock
FIG. 38
Screw locations for conduit box attachment in a pre-wall installation
2.
Remove any necessary wiring knockouts from the (optional) CB-TP12/15 conduit box (C in FIG. 39) where the
necessary cables are threaded through for connection to the touch panel.
3.
Thread the incoming RJ-45, Ethernet, and any other audio/video wiring through the knockouts. Refer to the Wiring
Guidelines for the 1200VG and 1500VG Panels section on page 57 for pinout descriptions. Leave enough slack in
the wiring to accommodate any re-positioning of the panel.
4.
Install the drywall/sheetrock before inserting the main NXD unit into the CB-TP12/15.

Installation of the NXD Touch Panel

The NXD panel can be installed either directly into the (optional) CB-TP12/15 or other solid surface environment using
the two different mounting options: drywall clips or solid surface screws. The following sections describe mounting the
touch panel directly into a pre-wall installed conduit box, a solid surface or drywall, and optional NXA-RK Rack Mount
Kit.

Installing the NXD panel within a Conduit Box

The conduit box must be mounted prior to continuing this section. Refer to the procedures in the Pre-wall Installation of
the Conduit Boxes section on page 47 for detailed pre-wall installation instructions. Verify that all necessary cables have
been threaded through the knockouts on the conduit box and the connections have been tested prior to installation of the
NXD panel.
1.
Remove the magnetic faceplate/bezel (A in FIG. 39) from the main NXD unit (B in FIG. 39) by gripping the
faceplate and pulling with gentle outward force.
48
Stud
Knockouts should be located on the left-side of the
conduit box, alongside the connectors
CB-TP Conduit Wallbox
Stud fastening holes
Use the four #4-40
Mounting Screws to
secure the NXD to the
conduit box at these
locations