Installation Of The Nxd Touch Panel; Installing The Nxd Panel Within A Conduit Box - AMX NXD-CA12 Operation/Reference Manual

12" & 15” modero touch panels
Hide thumbs Also See for NXD-CA12:
Table of Contents

Advertisement

Installation Procedures: 12" and 15" Panels
Drywall/
sheetrock
Mounting tabs
for NXD panel should
be flush with the outside of the sheetrock
FIG. 38
Screw locations for conduit box attachment in a pre-wall installation
2.
Remove any necessary wiring knockouts from the (optional) conduit box (CB-TP12/15)
(C in FIG. 38) where the necessary cables are threaded through for connection to the touch panel.
3.
Thread the incoming RJ-45, Ethernet, and any other audio/video wiring through the knockouts. Refer to
the Wiring Guidelines for the 12" and 15" Panels section on page 47 for pinout descriptions. Leave
enough slack in the wiring to accommodate any re-positioning of the panel.
4.
Install the drywall/sheetrock before inserting the main NXD unit into the CB-TP12/15.

Installation of the NXD Touch Panel

The NXD panel can be installed either directly into the (optional) CB-TP12/15 or other solid surface
environment using the two different mounting options: drywall clips or solid surface screws. The following
sections describe mounting the touch panel directly into a pre-wall installed conduit box, a solid surface or
drywall, and optional NXA-RK Rack Mount Kit.

Installing the NXD panel within a Conduit Box

The conduit box must be mounted prior to continuing this section. Refer to the procedures in the Pre-wall
Installation of the Conduit Boxes section on page 37 for detailed pre-wall installation instructions. Verify that
all necessary cables have been threaded through the knockouts on the conduit box and the connections have
been tested prior to installation of the NXD panel.
1.
Remove the magnetic faceplate/bezel (A in FIG. 39) from the main NXD unit (B in FIG. 39) by gripping
the faceplate and pulling with gentle outward force.
38
Stud
Knockouts should be located on the left-side of the
conduit box, alongside the connectors
CB-TP Conduit Wallbox
Stud fastening holes
Use the four #4-40
Mounting Screws to
secure the NXD to the
conduit box at these
locations