Front Panel Connectors - HP 83206A User Manual

Cellular adapter
Table of Contents

Advertisement

Front Panel Connectors

Analyzer Baseband
Direct Input to the Digital Analyzer for analyzing data streams. This input is
Data In
available through HP-IB control of the TDMA Encoder screen. (Not in use at this
time)
Operating Considerations
The rising edge of the Analyzer Data Clock In signal triggers the analyzer to read
this data.
The data must be present on the input for greater than or equal to 100 nsec before
the rising edge of the clock. The data must be stable on this input for
>=1.3microsec after being triggered by the Data Clock to correctly read the data.
Input level = TTL
Input impedance = 100 k
Data rates:
Analyzer Data
The rising edge of the signal applied to this front panel port causes the data on the
Clock In
Analyzer Baseband Data In connector to be sampled by the Digital Analyzer. (Not
in use at this time)
Operating Considerations
Input level = TTL
Input impedance = 100 k
Expected Clock Frequency:
48.6 kbit/sec
48.6 kbit/sec
Chapter 8, Connector Descriptions
Front Panel Connectors
245