Chapter 5, Programming the Cellular Adapter
Displaying the DCCH screens
Displaying the DCCH screens
Table 4
154
S:\HP83206A\USRGUIDE\MANUAL\prog.fm
Table 4
lists the command mnemonics for displaying the screens available in the
Cellular Adapter. For other screens, refer to the HP 8920 series Programmer's
Guide.
Note that to display the DCCH CALL CONTROL screen, you must display the
CALL CONTROL screen (ACNT) and change system type to DCCH.
DCCH Call Processing screen mnemonics
Screen
Call Control
Call Configure
Analog Measurement
Digital Measurement
Spectrum Analyzer
Sample syntax to display each DCCH Call Processing screen
! Display the Call Control screen
OUTPUT 714;"DISP ACNT"
! Change the system type to DCCH
OUTPUT 714;"CPR:CSYS 'DCCH'"
! Display the Call Configure screen
OUTPUT 714;"DISP DCON"
! Display the Analog Measurement screen
OUTPUT 714;"DISP CME"
! Display the Digital Measurement screen
OUTPUT 714;"DISP DME"
! Display the Spectrum Analyzer screen
OUTPUT 714;"DISP SAN"
Mnemonic
ACNT
DCON
CME
DME
SAN