Upgrades and Maintenance, cont'd
Changing the sync termination
In a sync BME, the first eight physical inputs on each I/O card are equipped with
sync termination DIP switches. Each switch provides the option of selecting either
510 ohms or 75 ohms.
Change the sync termination of the sync I/O card as follows:
1.
2.
C
3.
N All input numbers identified in figure 6-10 are physical inputs.
Figure 6-10 — Sync termination DIP switch
4.
5.
6-12
Matrix 12800 Switchers • Upgrades and Maintenance
If changing the configuration of an installed card, open and remove the front
door.
On the I/O cardcage door, turn the left and right knurled knobs ¼-turn
counterclockwise. Lower the door.
Do not touch the electronic components or the connectors on the backplane
or on the circuit cards without being electrically grounded. Handle circuit
cards by their edges only. ESD can damage ICs, even if you cannot feel,
see, or hear it.
Select the correct input card and the sync termination DIP switch specific
for the input to change (figure 6-10). Rock the DIP to the rear for 75-ohm
termination (the default setting). Rock the switch to the front for 510-ohm
termination.
DIP
Input
switch
card 1
1
Input 1
2
Input 2
3
Input 3
4
Input 4
5
Input 5
6
Input 6
7
Input 7
8
Input 8
Raise the I/O cardcage door to vertical and turn the left and right knurled
knobs ¼-turn clockwise.
Close the front door.
Switch
1
2
3
4
5
6
7
8
Input
Input
Input
card 2
card 3
card 4
Input 33
Input 65
Input 97
Input 34
Input 66
Input 98
Input 35
Input 67
Input 99
Input 36
Input 68
Input 100
Input 37
Input 69
Input 101
Input 38
Input 70
Input 102
Input 39
Input 71
Input 103
Input 40
Input 72
Input 104
DIP
Switches
Need help?
Do you have a question about the Matrix 12800 Wideband video and is the answer not in the manual?