Microprocessor problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 5, "Parts listing, IBM System x3530 M4 Type 7160," on page 265 to check if a component is a
consumable, structural, or FRU part.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Symptom
The server goes directly to the
POST Event Viewer when it is
turned on.

Monitor and video problems

Some IBM monitors have their own self-tests. If you suspect a problem with your
monitor, see the documentation that comes with the monitor for instructions for
testing and adjusting the monitor. If you cannot diagnose the problem, call for
service.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 5, "Parts listing, IBM System x3530 M4 Type 7160," on page 265 to check if a component is a
consumable, structural, or FRU part.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Symptom
Testing the monitor.
250
System x3530 M4 Type 7160: Installation and Service Guide
Action
1. Correct any errors that are indicated by the light path diagnostics LEDs (see
"Light path diagnostics LEDs" on page 109).
2. Make sure that the server supports all the microprocessors and that the
microprocessors match in speed, type, and cache size. To view the
microprocessor information, run the Setup utility and select System
Information → System Summary → Processor.
3. (Trained technician only) Make sure that microprocessor 1 is seated correctly.
4. (Trained technician only) Remove microprocessor 2 and restart the server.
5. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. (Trained technician only) Microprocessor
b. (Trained technician only) System board
Action
1. Make sure that the monitor cables are firmly connected.
2. Try using a different monitor on the server, or try using the monitor that is
being tested on a different server.
3. Run the diagnostic programs. If the monitor passes the diagnostic programs,
the problem might be a video device driver.
4. (Trained technician only) Replace the system board.