Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
806f0607-0301xxxx
An SM BIOS
806f0607-0302xxxx
Uncorrectable CPU
806f0607-2584xxxx
complex error for
Processor n has
asserted. (n =
microprocessor
number)
806f0807-0301xxxx
The Processor CPU n
806f0807-0302xxxx
has been disabled. (n
= microprocessor
number)
806f0807-2584xxxx
The Processor for
One of the CPUs has
been disabled.
806f0807-2584xxxx
The Processor for All
CPUs has been
disabled.
806f0a07-0301xxxx
The Processor CPU n
806f0a07-0302xxxx
is operating in a
Degraded State. (n =
microprocessor
number)
150
System x3530 M4 Type 7160: Installation and Service Guide
Error
The system
management
handler has
detected an
internal
microprocessor
error.
Info
A processor has
been disabled.
Info
A processor has
been disabled.
Info
A processor has
been disabled.
Warning
Throttling has
occurred for
microprocessor n.
(n =
microprocessor
number)
1. Make sure that the installed
microprocessors are compatible with
each other (see "Replacing a
microprocessor and heat sink" on
page 349 for information about
microprocessor requirements).
2. Update the server firmware to the
latest level (see "Updating the
firmware" on page 71).
3. (Trained technician only) Replace
the incompatible microprocessor
(see "Removing a microprocessor
and heat sink" on page 347 and
"Replacing a microprocessor and
heat sink" on page 349).
No action; information only.
No action; information only.
No action; information only.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow (front
and rear of the server), that the air
baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature. You
must be operating within the
specifications.
3. Make sure that the heat sink for
microprocessor nis installed
correctly.
4. (Trained technician only) Replace
microprocessor n.
(n = microprocessor number)