IBM System x3530 M4 Installation And Service Manual page 160

Type 7160
Hide thumbs Also See for System x3530 M4:
Table of Contents

Advertisement

Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
80010902-0701xxxx
Numeric sensor
Planar 5V going high
(upper critical) has
asserted.
80010202-0701xxxx
Numeric sensor
Planar 5V going low
(lower critical) has
asserted.
80010902-0701xxxx
Numeric sensor
Planar 12V going
high (upper critical)
has asserted.
80010202-0701xxxx
Numeric sensor
Planar 12V going
low (lower critical)
has asserted.
80010002-0701xxxx
Numeric sensor
Planar VBAT going
low (lower
non-critical) has
asserted.
80010202-0701xxxx
Numeric sensor
Planar VBAT going
low (lower critical)
has asserted.
806f0008-0a01xxxx
The Power Supply
806f0008-0a02xxxx
(Power Supply n)
presence has been
added to container.
(n = power supply
number)
806f0009-1301xxxx
The Power Supply
(Power Supply n)
has been turned off.
144
System x3530 M4 Type 7160: Installation and Service Guide
Error
An upper critical
sensor going high
has asserted.
Error
A lower critical
sensor going low
has asserted.
Error
An upper critical
sensor going high
has asserted.
Error
A lower critical
sensor going low
has asserted.
Warning
A lower critical
sensor going low
has asserted.
Error
A lower critical
sensor going low
has asserted.
Info
Power supply n
has been added. (n
= power supply
number)
Info
This message is for
the use case when
an implementation
has detected a
Power Unit that
has been Disabled.
(Trained technician only) Replace the
system board (see "Removing the
system board" on page 354 and
"Replacing the system board" on page
359).
(Trained technician only) Replace the
system board (see "Removing the
system board" on page 354 and
"Replacing the system board" on page
359).
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace
the system board.
(n = power supply number)
1. Check power supply n LED.
2. Remove the failing power supply.
3. Follow actions for OVER SPEC LED
in System-board LEDs.
4. (Trained technician only) Replace
the system board.
(n = power supply number)
Replace the system battery (see
"Removing the system battery" on page
332 and "Replacing the system battery"
on page 334).
Replace the system battery (see
"Removing the system battery" on page
332 and "Replacing the system battery"
on page 334).
No action; information only.
No action; information only.