Table 1. Server features and specifications (continued)
RAID controllers:
The following RAID options are
available for the server:
v ServeRAID H1110 SAS/SATA
Controller for System x
v ServeRAID M1115 SAS/SATA
Controller for System x
v ServeRAID M5110 SAS/SATA
Controller for IBM System x
v ServeRAID M5120 SAS/SATA
Controller for IBM System x
v ServeRAID M5100 Series Battery
Kit for IBM System x
v ServeRAID M5100 Series 512MB
Cache/RAID 5 Upgrade for IBM
System x
v ServeRAID M5100 Series 512MB
Flash/RAID 5 Upgrade for IBM
System x
v ServeRAID M5100 Series Zero
Cache/RAID 5 Upgrade for IBM
System x
v ServeRAID M5100 Series 1GB
Flash/RAID Upgrade for IBM
System x
v ServeRAID C105 for IBM System X
Size:
v Height: 43 mm ( 1.7 inches, 1U)
v Depth: 673.1 mm (26.5 inches)
v Width: 447 mm (17.6 inches)
v Maximum weight: 15.8 kg (33.8 lb)
when fully configured
Acoustical noise emissions:
v Sound power, idling: 6.5 bels
v Sound power, operating: 6.5 bels
Environment:
v Air temperature:
– Server on: 5°C to 40°C (41°F to
104°F); altitude: 0 to 915 m (3000
ft)
– Server on: 5°C to 32°C (41°F to
89.6°F); altitude: 915 m (3000 ft)
to 2134 m (7000 ft)
– Server on: 5°C to 28°C (41°F to
82.4°F); altitude: 2134 m (7000
ft) to 3050 m (10000 ft)
– Server off: 5°C to 45°C (41° to
113°F)
– Shipment: -40°C to +60°C (-40°F
to 140°F)
v Humidity:
– Server on: 8% to 85%; maximum
dew point: 24°C (75.2°F);
maximum rate of change 5
°C/hr
– Server off: 8% to 80%; maximum
dew point: 27°C (80°F)
– Shipment: 5% to 100%
v Design to ASHRAE Class A3:
– Ambient of 35°C to 40°C (95°F
to 104°F), with relaxed support
– Support cloud like workload
with no performance
degradation acceptable
(Turbo-Off)
– Under no circumstance, can any
combination of worst case
workload and configuration
result in system shutdown or
design exposure at 40°C (104°F)
v Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone or
in combination with other
environmental factors such as
humidity or temperature might
pose a risk to the server. For
information about the limits for
particulates and gases, see
"Particulate contamination" on
page 373.
Chapter 1. The IBM System x3530 M4 Type 7160 server
Heat output:
Approximate heat output:
v Minimum configuration: 406 Btu
per hour (119 watts)
v Maximum configuration: 2627.3
Btu per hour (770 watts)
Electrical input:
v Sine-wave input (50 - 60 Hz)
required
v Input voltage automatically
selected
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
v Input kilovolt-amperes (kVA),
approximately:
– Minimum: 0.12 kVA
– Maximum: 0.78 kVA
Notes:
1. Power consumption and heat
output vary depending on the
number and type of optional
features installed and the
power-management optional
features in use.
2. The noise emission level stated is
the declared (upper limit) sound
power level, in bels, for a random
sample of machines. All
measurements are made in
accordance with ISO 7779 and
reported in conformance with ISO
9296.