IBM System x3530 M4 Installation And Service Manual page 247

Type 7160
Hide thumbs Also See for System x3530 M4:
Table of Contents

Advertisement

Table 14. DSA messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
v Go to the IBM support web site at http://www.ibm.com/supportportal/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
202-901-xxx
Memory
State
Description
Memory
Failed
Test failure.
Stress Test
Action
1. Run the standard memory test to validate
all memory.
2. Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
DSA.
3. Turn off the system and disconnect it
from power.
4. Reseat the DIMMs.
5. Reconnect the system to power and turn
on the system.
6. Run the test again.
7. Run the standard memory test to validate
all memory.
8. If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/systems/
support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Chapter 4. Troubleshooting
231

Advertisement

Table of Contents
loading

Table of Contents