IBM System x3530 M4 Installation And Service Manual page 180

Type 7160
Hide thumbs Also See for System x3530 M4:
Table of Contents

Advertisement

Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
816f000d-0400xxxx
The Drive n Status
816f000d-0401xxxx
has been removed
816f000d-0402xxxx
from unit. (n = hard
816f000d-0403xxxx
disk drive number)
816f000d-0404xxxx
816f000d-0405xxxx
816f000d-0406xxxx
816f000d-0407xxxx
806f010d-0400xxxx
The Drive n Status
806f010d-0401xxxx
has been disabled
806f010d-0402xxxx
due to a detected
806f010d-0403xxxx
fault. (n = hard disk
806f010d-0404xxxx
drive number)
806f010d-0405xxxx
806f010d-0406xxxx
806f010d-0407xxxx
806f020d-0400xxxx
The Drive n Status
806f020d-0401xxxx
has a predictive
806f020d-0402xxxx
failure. (n = hard
806f020d-0403xxxx
disk drive number)
806f020d-0404xxxx
806f020d-0405xxxx
806f020d-0406xxxx
806f020d-0407xxxx
806f050d-0400xxxx
Array %1 is in
806f050d-0401xxxx
critical condition.(%1
806f050d-0402xxxx
=
806f050d-0403xxxx
CIM_ComputerSystem.
806f050d-0404xxxx
ElementName)
806f050d-0405xxxx
806f050d-0406xxxx
806f050d-0407xxxx
164
System x3530 M4 Type 7160: Installation and Service Guide
Error
A drive has been
removed.
Error
A drive has been
disabled because of
a fault.
Error
A predictive failure
has been detected
for drive n. (n =
hard disk drive
number)
Error
An array is in a
critical state.
(Sensor = Drive n
Status) (n = hard
disk drive number)
1. Reseat hard disk drive n.(n = hard
disk drive number). Wait 1 minute
or more before reinstalling the
drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware
and RAID controller firmware is at
the latest level.
4. Check the SAS cable.
1. Run the hard disk drive diagnostic
test on drive n.
2. Reseat the following components:
a. Hard disk drive (wait 1 minute
or more before reinstalling the
drive).
b. Cable from the system board to
the backplane
3. Replace the following components
one at a time, in the order shown,
restarting the server each time:
a. Hard disk drive
b. Cable from the system board to
the backplane
c. Hard disk drive backplane
(n = hard disk drive number)
1. Replace the hard drive n.
(n = hard disk drive number)
1. Make sure that the RAID adapter
firmware and hard disk drive
firmware is at the latest level.
2. Make sure that the SAS cable is
connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is
indicated by a lit status LED.

Advertisement

Table of Contents
loading