IBM System x3530 M4 Installation And Service Manual page 175

Type 7160
Hide thumbs Also See for System x3530 M4:
Table of Contents

Advertisement

Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
806f040c-2581xxxx
Memory DIMM
disabled for One of
the DIMMs.
806f040c-2581xxxx
Memory DIMM
disabled for All
DIMMs.
Info
DIMM disabled.
Info
DIMM disabled.
1. Make sure the DIMM is installed
correctly (see "Replacing a memory
module" on page 313).
2. If the DIMM was disabled because
of a memory fault (memory
uncorrectable error or memory
logging limit reached), follow the
suggested actions for that error
event and restart the server.
3. Check the IBM support website for
an applicable retain tip or firmware
update that applies to this memory
event. If no memory fault is
recorded in the logs and no DIMM
connector error LED is lit, you can
re-enable the DIMM through the
Setup utility or the Advanced
Settings Utility (ASU).
1. Make sure the DIMM is installed
correctly (see "Replacing a memory
module" on page 313).
2. If the DIMM was disabled because
of a memory fault (memory
uncorrectable error or memory
logging limit reached), follow the
suggested actions for that error
event and restart the server.
3. Check the IBM support website for
an applicable retain tip or firmware
update that applies to this memory
event. If no memory fault is
recorded in the logs and no DIMM
connector error LED is lit, you can
re-enable the DIMM through the
Setup utility or the Advanced
Settings Utility (ASU).
Chapter 4. Troubleshooting
159

Advertisement

Table of Contents
loading