Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
40000022-00000000
SSL data in the IMM
configuration data is
invalid. Clearing
configuration data
region and disabling
SSL+H25.
40000023-00000000
Flash of %1 from %2
succeeded for user
%3.(%1 =
CIM_ManagedElement.ElementName;
%2 = Web or
LegacyCLI; %3 =
user ID)
40000024-00000000
Flash of %1 from %2
failed for user
%3.(%1 =
CIM_ManagedElement.ElementName;
%2 = Web or
LegacyCLI; %3 =
user ID)
Error
There is a problem
with the certificate
that has been
imported into the
IMM. The
imported certificate
must contain a
public key that
corresponds to the
key pair that was
previously
generated through
the Generate a
New Key and
Certificate Signing
Request link.
Info
A user has
successfully
updated one of the
following firmware
components:
v IMM main
application
v IMM boot ROM
v Server firmware
(UEFI)
v Diagnostics
v System power
backplane
v Remote
expansion
enclosure power
backplane
v Integrated
service processor
v Remote
expansion
enclosure
processor
Info
An attempt to
update a firmware
component from
the interface and
IP address has
failed.
1. Make sure that the certificate that
you are importing is correct.
2. Try to import the certificate again.
No action; information only.
Try to update the firmware again.