IBM System x3530 M4 Installation And Service Manual page 140

Type 7160
Hide thumbs Also See for System x3530 M4:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Diagnostic
code
Message
I.18006
[I.18006] A mismatch between
the maximum allowed QPI link
speed has been detected for one
or more processor packages.
I.18007
[I.18007] A power segment
mismatch has been detected for
one or more processor
packages.
I.18008
[I.18008] Currently, there is no
additional information for this
event.
124
System x3530 M4 Type 7160: Installation and Service Guide
Description
Processors have mismatched
QPI Speed.
Processors have mismatched
Power Segments.
Processors have mismatched
Internal DDR3 Frequency.
Action
1. Make sure that the microprocessor
is on the ServerProven website at
http://www.ibm.com/systems/
info/x86servers/serverproven/
compat/us/ .
2. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this problem.
3. (Trained technician only) Remove
and replace the affected
microprocessor (error LED is lit)
with a supported type (see
"Replacing a microprocessor and
heat sink" on page 349).
1. Make sure that the microprocessor
is on the ServerProven website at
http://www.ibm.com/systems/
info/x86servers/serverproven/
compat/us/ .
2. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this problem.
3. (Trained technician only) Remove
and replace the affected
microprocessor (error LED is lit)
with a supported type (see
"Replacing a microprocessor and
heat sink" on page 349).
1. Make sure that the microprocessor
is on the ServerProven website at
http://www.ibm.com/systems/
info/x86servers/serverproven/
compat/us/ .
2. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this problem.
3. (Trained technician only) Remove
and replace the affected
microprocessor (error LED is lit)
with a supported type (see
"Replacing a microprocessor and
heat sink" on page 349).

Advertisement

Table of Contents
loading

Table of Contents