3.2.09 Filter Assembly

Perform these procedures first:
- 3.2.01 ( )
- 3.2.04 ( )
- Working from the bottom of the chassis, push on and release the claw (1) of the filter
assembly (2).
- Lift the AC connector (3) and the AC power switch (4) from the two guides on the main
frame.
- Remove the filter assembly.
- The filter assembly contains a 1.5 amp fuse (5).
Part
Item
Number
Description
P/N
Filter: (Assembly)
55503103
Service Guide ML320/ML321
Chapter 3 Maintenance & Disassembly
Product
Comment
Both
RSPL
App. B
Revision
Reference
A B C D
B.2.03 04 05
AC 120 V