Service Guide ML320/ML321
Chapter 2 Principles of Operation

2.3.02 Interface Control

Parallel Interface
In Rev A, B, and C printers, the data from the host is input through connector CN5 to the
interface LSI Q11.
In Rev D printers, the data from the host is input through connector CN6 to the interface LSI Q3.
The interface LSI latches this input data in synchronization with the STB-N signal. The BUSY
signal is active while this data is being processed. When processing is complete, the BUSY signal
is turned OFF, and an ACK-N is sent to the host (to request more data).
The BUSY signal is also sent to the host whenever the printer is incapable of receiving data.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)