SIP User's Manual
3.2.5
Replacing Modules
To replace the device's modules, you must use the Web interface in combination with
physical removal and insertion of the modules. In other words, when you replace a module,
you first need to 'software-remove' it, then extract it physically from the chassis and insert a
new module, and then 'software-insert' it using the Web interface. The software removal
and insertion is performed in the 'Home' page.
Warnings:
Note:
To replace a module:
1.
Remove the module by performing the following:
a.
In the 'Home' page, click the title of the module that you want to replace; the
Remove Module
Figure 3-35: Remove Module Button Appears after Clicking Module Name
b.
Click the Remove Module
confirm module removal:
Figure 3-36: Module Removal Confirmation Message Box
Version 6.0
•
A module must be replaced with the same type of module and in the
same module slot number. For example, a module with two digital spans
in Slot 1 must be replaced with a module with two digital spans in Slot 1.
•
When only one module is available, removal of the module causes the
device to reset.
•
Before inserting a module into a previously empty slot, you must power
down the device.
This section is applicable only to Mediant 1000.
button appears:
button; a message box appears requesting you to
59
3. Web-Based Management
March 2010