For example, to configure the dial tone to 440 Hz only, enter the following text:
[NUMBER OF CALL PROGRESS TONES]
Number of Call Progress Tones=1
#Dial Tone
[CALL PROGRESS TONE #0]
Tone Type=1
Tone Form =1 (continuous)
Low Freq [Hz]=440
High Freq [Hz]=0
Low Freq Level [-dBm]=10 (-10 dBm)
High Freq Level [-dBm]=32 (use 32 only if a single tone is
required)
First Signal On Time [10msec]=300; the dial tone is detected after
3 sec
First Signal Off Time [10msec]=0
Second Signal On Time [10msec]=0
Second Signal Off Time [10msec]=0
8.1.1

Distinctive Ringing

Distinctive Ringing is applicable only to FXS interfaces. Using the Distinctive Ringing
section of the Call Progress Tones auxiliary file, you can create up to 16 Distinctive Ringing
patterns. Each ringing pattern configures the ringing tone frequency and up to four ringing
cadences. The same ringing frequency is used for all the ringing pattern cadences. The
ringing frequency can be configured in the range of 10 to 200 Hz with a 5 Hz resolution.
Each of the ringing pattern cadences is specified by the following parameters:
Burst Ring On Time:
ringing pattern. The burst relates to On time and the Off time of the same cadence. It
must appear between 'First/Second/Third/Fourth' string and the 'Ring On/Off Time'
This cadence rings once during the ringing pattern. Otherwise, the cadence is
interpreted as cyclic: it repeats for every ringing cycle.
Ring On Time:
Ring Off Time:
The Distinctive Ringing section of the
[NUMBER OF DISTINCTIVE RINGING PATTERNS]:
'Number of Distinctive Ringing Patterns' defining the number of Distinctive Ringing
signals that are defined in the file.
[Ringing Pattern #X]:
not exceeding the number of Distinctive Ringing patterns defined in the first section
minus 1) using the following keys:
Ring Type: Must be equal to the Ringing Pattern number.
Freq [Hz]: Frequency in hertz of the ringing tone.
First (Burst) Ring On Time [10 msec]: 'Ring On' period (in 10 msec units) for
the first cadence on-off cycle.
SIP User's Manual
Configures the cadence to be a burst cadence in the entire
Specifies the duration of the ringing signal.
Specifies the silence period of the cadence.
ini
file format contains the following strings:
Contains the Xth ringing pattern definition (starting from 0 and
476
Mediant 600 & Mediant 1000
Contains the following key:
Document #: LTRT-83306